Candela GentleMAX Pro
Candela’s specialist dual-wavelength laser hair removal device.
Candela GentleMAX Pro At GoLaser
As one of Candela’s latest generation of lasers, the Candela GentleMAX Pro has become one of the most popular devices on the market, excelling at hair removal and other laser treatments. A dual-laser output of 755nm and 1064nm produced by an Alexandrite laser and an Nd:YAG laser, respectively, allows the Candela GentleMAX Pro to treat all skin types safely.
The specialised Candela GentleMAX Pro handpiece enables the use of the device on most areas of the body, with spot sizes of 20mm, 22mm, and 24mm – each can be selected quickly by the practitioner. The revolutionary design and powerful laser combination make the Candela GentleMAX Pro one of the fastest dual-wavelength lasers on the market.
Zimmer Cryo 6 supports the Candela GentleMAX Pro throughout treatment, maintaining complete patient comfort throughout treatment sessions with active cooling technology that maintains skin surface temperature to protect the skin being treated and the surrounding tissue, resulting in a virtually pain-free treatment.
Candela GentleMax Pro Features
All Skin
Candela GentleMax Pro can be used on all skin types.
Cooling
Continuous cooling throughout treatment, provided by Zimmer Cryo 6.
Dual Laser
Candela GentleMax Pro features a 755nm Alexandrite laser and a 1064nm Nd:YAG laser.
Speed
Candela GentleMax Pro is one of the world’s fastest dual-wavelength hair removal lasers.
Candela GentleMax Pro
Treatments
The Candela GentleMAX Pro is a versatile laser capable of treating a variety of skin conditions, including:
Laser Hair Removal
Laser hair removal is a cosmetic procedure that uses concentrated light beams to target and destroy hair follicles, reducing or eliminating hair growth.
Spider Veins
Spider veins are small, dilated blood vessels that appear close to the skin’s surface, often looking like red, blue, or purple web-like patterns.
Age Spots
Age spots are flat, dark areas on the skin that develop due to prolonged sun exposure and ageing, typically appearing on areas like the face, hands, and arms.
Skin Pigmentation
Skin pigmentation is a change in the colouring of the skin, which is caused by a variation in the amount and type of melanin produced by skin cells, resulting in abnormal skin tone.
Vascular Anomalies
Vascular anomalies are abnormal growths or formations in blood vessels or lymphatic vessels, which can be present at birth or develop later in life, and can vary widely in severity and appearance.
Telangiectasia
Telangiectasia is a condition where small blood vessels near the surface of the skin become dilated and visible, often appearing as red or purple thread-like lines.
Sun Damaged Skin
Sun-damaged skin refers to skin that has been harmed by excessive exposure to ultraviolet (UV) rays, leading to premature ageing, wrinkles, discolouration, and an increased risk of skin cancer.
Candela GentleMAX Pro Spot Sizes & Treatment Speed
To help you plan session lengths and treatment room scheduling, the following timings are based on a consistent 100 cm² treatment area with light overlap at typical clinical settings. These comparisons give a reliable guide when selecting the appropriate handpiece and spot size for the Candela GentleMAX Pro.
Standard Handpiece (DCD or ACC With Distance Gauges)
– 18 mm: approx. 40 to 60 seconds
– 15 mm: approx. 45 to 75 seconds
– 12 mm: approx. 60 to 90 seconds
– 10 mm: approx. 90 to 150 seconds
– 8 mm: approx. 2 to 3.5 minutes
– 6 mm: approx. 3 to 5 minutes
Speciality Delivery System
– 5 mm: approx. 5 to 8 minutes
– 3 mm: approx. 10 to 15 minutes
– 1.5 mm: approx. 15 to 25 minutes
– 3 x 10 mm rectangle: useful for linear targets, typically between 5 mm and 10 mm timings
Large Spot Delivery System
– 24 mm: approx. 20 to 30 seconds
– 22 mm: approx. 25 to 35 seconds
– 20 mm: approx. 30 to 45 seconds
Overall, spot sizes available include 1.5, 3, 3 x 10, 5, 6, 8, 10, 12, 15, 18, 20, 22, and 24 mm across the Speciality, Standard, and Large Spot Delivery handpieces. Speak to us about servicing, refurbishment, or sales for any Candela GentleMAX Pro handpieces.
Device Cooling & Patient Comfort
Effective epidermal protection is essential for both safety and patient experience during laser procedures. The GentleMAX Pro is designed to integrate cooling directly into the treatment workflow, reducing discomfort while safeguarding the skin. By lowering surface temperature, clinics can treat more efficiently at therapeutic fluences without compromising comfort or outcomes.
Routine checks of cooling performance and delivery components are key to maintaining consistent results, particularly when using larger spot sizes or higher repetition rates. Well-maintained cooling not only improves patient tolerance but also supports smooth stacking and predictable coverage across treatment areas.
ACC & DCDTM Handpiece Options
The GentleMAX Pro handpieces are equipped with integrated cooling options tailored to different clinic preferences. The Air Cooling Compatible (ACC) handpiece connects to external chilled air systems, while the patented Dynamic Cooling Device™ (DCD™) handpiece delivers precise cryogen bursts to the skin for continuous temperature control. Both are designed to maximise comfort and safety across a wide range of treatments.
GoLaser sells, buys, and repairs all Candela GentleMAX Pro handpieces, including ACC and DCD™ options. Contact our team to discuss availability, servicing, or replacement handpieces for your system.

Consumables & Spare Parts
Keep your GentleMAX Pro running reliably with approved consumables and parts. Consumable items include DCD cryogen canisters, distance gauges and sliders, protective windows, optical fibres, handpiece shells and tips, and filters for the cooling system. Stock levels can vary, so we advise clinics to hold a small buffer of critical spares.
If you need parts or advice on compatibility by serial number, get in touch, and our engineering team will match the correct component set for your device and handpieces.
Preventive Maintenance For Candela GentleMAX Pro
Regular maintenance is essential to maximise uptime and protect the performance of the Candela GentleMAX Pro. Daily visual checks, weekly cleaning, and routine inspections help prevent issues, while annual or usage-based servicing ensures calibration, safety testing, and cooling system verification are all up to standard. High-volume clinics may also benefit from mid-cycle servicing to keep optics clean and replace high-wear items before performance is affected.
At GoLaser, we provide fast, reliable diagnostics, servicing, and repairs to minimise downtime and return your device to optimal condition. Every service includes a detailed report with test results for LPA and insurance compliance. Share your system details with our team and we will advise the most cost-effective route to keep your GentleMAX Pro operating at its best.


Common Faults & Fault Codes
Candela devices are known for reliability, but the GentleMAX Pro may occasionally display fault codes such as DCD spray faults, low cryogen, interlock errors, overtemperature, or water flow issues. These can stem from consumables, connectors, or internal assemblies and should be checked promptly to protect the system. For quick reference, visit our Candela fault codes page, or contact our engineers if errors persist for guidance on safe checks and next steps.
Feature |
Specification |
| Laser Types | Alexandrite & Nd:YAG |
| Wavelength | 755nm, 1064nm |
| Energy | 53 J (Alexandrite) • 80 J (Nd:YAG) |
| Pulse Duration | 0.250 ms to 100 ms |
| Spot Sizes (Standard)s | 6 mm, 8 mm, 10 mm, 12 mm, 15 mm, 18 mm |
| Specialty / Large Spot Sizes | 1.5 mm, 3 mm, 5 mm, 3 × 10 mm; also 20 mm, 22 mm, 24 mm |
| Beam Delivery | Lens-coupled optical fibre + handpiece |
| Pulse Control | Foot switch; finger (hand) switch |
| Dimensions | 107 cm (H) × 46 cm (W) × 69 cm (D) |
| Weight | Approx. 118kg |
Candela GentleMAX Pro FAQs
Find the answers to your questions about the Candela GentleMAX Pro in our list of frequently asked questions below:
Expert engineers with years of experience working with a wide range of laser devices.
High-quality parts and equipment to ensure that your Laser or IPL device is functioning optimally.
Comprehensive maintenance, repairs, and upgrades to keep your laser or IPL device running at peak performance.
Fast turnaround times and competitive pricing.
Personalised service tailored to your clinic’s specific needs and requirements.